2020 L.B. White Sentinel® V.2 Radiant Tube Heater 150-40

2020 L.B. White Sentinel® V.2 Radiant Tube Heater 150-40

Swipe to View More

  • Year 2020
  • Make L.B. White
  • Model Sentinel® V.2 Radiant Tube Heater
2020 L.B. White Sentinel® V.2 Radiant Tube Heater 150-40

2020 L.B. White Sentinel® V.2 Radiant Tube Heater 150-40

2020 L.B. White Sentinel® V.2 Radiant Tube Heater 150-40

The L.B. White Sentinel® v.2 is the only radiant tube heater designed specifically for poultry houses. The Sentinel®s advanced reflector and pressurized burner design delivers maximum heat distribution out to the sidewalls as well as even heat down the length of the tube which gives more consistent heat coverage throughout the building. With interlocking tubes and self-leveling hangers included as part of a complete installation kit, the Sentinel® is extremely easy to install and even easier to maintain. The Sentinel®s ability to use fresh air from a side wall or attic helps it run cleaner and require less maintenance.

L.B. White has perfected every aspect of our Sentinel® v.2 radiant tube heater which is designed to withstand the harsh environments of poultry facilities. This has led to our reputation for reliability, durability and serviceability in the field.

Features may include:

Key features of the Sentinel® v.2 Radiant Tube Heater for poultry houses:

  • 30 foot, 40 foot and 50 foot tube lengths
  • A variety of models with heat output ratings from 100,000 to 150,000 Btu/h
  • Natural gas or liquid propane gas models
  • Choose from single stage or two stage models
  • Dependable spark ignition
  • 100% test fired at our plant
  • Easy installation and maintenance

Determine size and quantity of radiant tube heaters for ventilated poultry houses and broiler houses

  • Call our technical experts to help you select the correct size and quantity of heaters for your poultry production enterprise.

Electric

Electrical Electrical Supply (Volts / Hz / Phase): 115 / 60 / 1

Operational

Operating Conditions Rating: Max Input (Btuh) Single Stage 150,000 | Fuel Consumption (max.): Liquid Propane Gas (lbs./hr.) 7.1 | Fuel Consumption (max.): Natural Gas (cu. ft./hr.) 150 | Ventilation (CFM): 140 | Inlet Gas Supply Pressure LP Gas min. / max. (in. W.C.): 11.0 - 13.5 | Inlet Gas Supply Pressure Natural Gas min. / max. (in. W.C.): 7.0 - 13.5

Dimensions

Length Tube (ft.): 40 | Heater Case Dimensions (in.): 25.5
Height Minimum Installation (ft.): 6 | Heater Case Dimensions (in.): 9.75
Width Heater Case Dimensions (in.): 16
Dimensions Min Clearance to Combustibles Top (ft.): 1 | Min Clearance to Combustibles Below (ft.): 6 | Min Clearance to Combustibles Side (ft.): 6

Weights

Weight Net: 180 lbs
Weight, As Shipped 200 lbs

Features

Construction Material Reflector Material: Polished Aluminum | Tube Material First 10 ft. section: Aluminized Steel | Tube Material Balance: Steel

Product Photography