2020 L.B. White L-40 Low Pressure Radiant Heat Brooder Base

2020 L.B. White L-40 Low Pressure Radiant Heat Brooder Base

Swipe to View More

  • Year 2020
  • Make L.B. White
  • Model L-40 Low Pressure Radiant Heat Brooder
2020 L.B. White L-40 Low Pressure Radiant Heat Brooder Base

2020 L.B. White L-40 Low Pressure Radiant Heat Brooder Base

2020 L.B. White L-40 Low Pressure Radiant Heat Brooder

Low profile, energy efficient, far reaching heat is what is provided with the L.B. White L-40 radiant brooder. This low pressure brooder has a simple design, making assembly time much quicker than other low pressure brooders. Fewer parts and connections make repair easy.

L.B White's L-40 can be used to replace one or all competitive 40,000 btu/h brooders in a poultry house as connections match. Simply unplug the competitive unit and plug in the L-40 to utilize the consistent and far reaching heat pattern. No need to worry about gas type as all units ship with the ability to use either LP or Natural gas with the switch of an orifice which is stored on the unit.

Backed by L.B. White's 65 plus years of heating experience, technical know-how, and user oriented customer support, feel confident when heating your poultry house with the L-40 low pressure brooder!

Features may include:

Key features of L.B. White L-40 Chick Brooder Heater for poultry production

  • 40,000 Btu/h
  • Spark Ignition
  • Propane and natural gas dual fuel model
  • Low Profile
  • Wide heat coverage
  • 100% Test fired
  • Components highly resistant to corrosion
  • Ship in master packs of 8
  • No filter - No additional accessories to clean!

Certifications of the L-40 Chicken and Poultry Heater

  • L.B. White L-40 radiant brooder heaters help producers control poultry house climates and are available in CSA U.S. and Canada certified models.

Determine size and quantity of chick brooder heaters for poultry houses

  • Call our technical experts to help you select the correct quantity of L.B. White L-40 brooder heaters for your poultry production houses.

Electric

Electrical Electrical Requirements: Spark Ignition 24 VAC / 60HZ

Operational

Operating Conditions Input (Btu/h): 40,000 | Inlet Gas Supply Pressure: Propane (inches of W.C.) 11-14| Inlet Gas Supply Pressure: Natural Gas (inches of W.C.) 7-14 | Fuel Consumption (max.): Liquid Propane Gas (lbs/hr) 1.85 | Fuel Consumption (max.): Natural Gas (cu. ft/hr) 40.0 | Ventilation (CFM): 468

Dimensions

Dimensions Canopy Diameter: 31.5 | Center Spacing (ft.): 25 - 40 | Minimum Clearance to Combustibles (inches): Top 14 | Minimum Clearance to Combustibles (inches): Side 36 | Minimum Clearance to Combustibles (inches): Below 54
Height Installation Broilers: 5 - 6 ft | Installation Turkeys: 4.5 - 5.5 ft | 14 in

Weights

Weight Net: 14.5 lbs

Features

Construction Material Canopy: Polished Aluminum

Product Photography